Categories
Model | EPS-35-5 | EPS-35-12 | EPS-35-15 | EPS-35-24 | EPS-35-36 | EPS-35-48 | ||
Output | DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V | |
Rated Current | 7A | 3A | 2.3A | 1.5A | 1A | 0.75A | ||
Current Range | 0~7A | 0~3A | 0~2.3A | 0~1.5A | 0~1A | 0~0.75A | ||
Ripple& Noised(Max) | 50mV | 120mV | 150mV | 200mV | 200mV | 200mV | ||
Output Voltage adjustment range | ±10% of rated output voltage | |||||||
Stabilization Accuracy | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
Power supply voltage adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
Load Regulation | ±1.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
Setup,Rise time | <1S (230VAC Input), <2S (115VAC Input) | |||||||
Hold up Time | <70ms/230VAC 15ms/115VAC | |||||||
Input | Voltage Range | 88Vac~264Vac | ||||||
Frequency Range | 47Hz~63Hz | |||||||
Efficiency | 78% | 81% | 81% | 83% | 83% | 83% | ||
Inrush Current (Typ.) | <30A@230VAC <20A@115VAC Cold start | |||||||
Protection | Overload | 105%~135% Rated output current, downtime, self-recovery | ||||||
Overvoltage | 120%~130% Rated output voltage, downtime, self-recovery | |||||||
Short circuit | Can be short-circuited for a long time, and can automatically recover after eliminating the short-circuit | |||||||
Enviroment | Working Temp.& Humidity | -30℃~70℃;25%~90%RH | ||||||
Storage Temp.& Humidity | -40℃~85℃;10%~95%RH | |||||||
Safety& EMC Standard | Safety Standard | Refer to GB4943/EN60950,UL62368-1,TUV EN62368-1 | ||||||
Insulation Resistance | I/P-O/P:3KVac; .I/P-FG:1.5KVac; O/P-FG:0.5KVDC | |||||||
Others | MTBF (MIL-HDBK-217F) | More than 100,000Hrs (25℃, full load) | ||||||
Dimenson(L*W*H) | 110*78*35mm | |||||||
Packing | 400g/PCS | |||||||
Cooling Method | Natural cooling | |||||||
Note | 1.All parameters NOT specially mentioned are measured at rated input, rated load, and 25°C ambient temperature. |